Secure Checkout
Hi-Vol TSP Air Sampler System with PLUS Technology - Lead Monitoring

Thumbnail Filmstrip of Hi-Vol TSP Air Sampler System with PLUS Technology - Lead Monitoring Images

    Purchase Hi-Vol TSP Air Sampler System with PLUS Technology - Lead Monitoring

    Hi-Vol TSP Air Sampler System with PLUS Technology - Lead Monitoring SKU: TE-HVPLUS

    The TE-HVPLUS is a high-volume air sampler system specifically configured for Total Suspended Particulate (TSP) collection in lead monitoring applications. This system provides measurement of the mass concentration of total suspended particulate matter in ambient air for determining compliance with national ambient air quality standards, making it essential for EPA-mandated lead monitoring programs where the primary health-based standard is 0.15 µg/m³ of Pb measured in TSP.

    PLUS Technology Flow Control

    The PLUS controller delivers microprocessor-based flow control with integrated ambient temperature and barometric pressure sensors for real-time environmental compensation. The system's built-in temperature and barometric pressure sensors along with the microprocessor-based mass flow controller allow the system to accurately calculate the flow rate. The PLUS technology flow controllers include a built-in digital timer with internal battery backup, multiple elapsed time indicators, and four data logs with an external USB drive for data retrieval.

    EPA Reference Method Compliance

    This sampler operates in full compliance with 40 CFR Part 50, Appendix B, the EPA reference method for TSP. The high-volume sampler collects particles with aerodynamic diameters of approximately 100 µm or less at 40-60 cubic feet per minute with the sampling rate held constant over the sampling period. The FRM uses the ambient air sample collection procedures of the high-volume TSP method (40 CFR Part 50, Appendix B) and the analytical procedure for the measurement of Pb based on ICP-MS.

    Key Specifications

    • Power: 110V, 60Hz configuration
    • Flow rate: 39-60 ft³/min constant sampling rate
    • Sampling period: 1,440 ±60 minutes for valid sample collection
    • Motor: Brush-style drive system
    • Controller: MFC PLUS with microprocessor control
    • Timer: Digital with battery backup
    • Data logging: Four independent data logs with USB export

    Complete Sampling System

    The system includes an aluminum outdoor shelter designed for all-weather operation. TSP high volume air samplers are housed in an anodized aluminum shelter with a gabled roof assembly designed to allow particulate matter to be drawn onto the filter from all four sides, with rugged construction that withstands the elements with minimal maintenance. The integrated elapsed time indicator tracks motor operation hours for maintenance scheduling and sample verification.

    Lead Monitoring Applications

    Essential for ambient air monitoring networks conducting lead surveillance near industrial sources, roadways, or other potential emission points. Pb-TSP is collected for 24 hours on a TSP filter as described in Appendix B of part 50, the Reference Method for the Determination of Suspended Particulate Matter in the Atmosphere (High-Volume Method). The collected samples undergo subsequent laboratory analysis for lead content determination using approved analytical methods.

    This configuration provides reliable, EPA-compliant particulate collection with advanced PLUS technology for operators requiring precise environmental monitoring data and simplified system operation in lead monitoring applications.

    Controller Type
    MFC PLUS
    Motor Type
    Brush
    Power Configuration
    110volt, 60hz
    Sample Type
    TSP
    Timer Type
    Digital
    Uses PLUS tech?
    Yes