TE-6070V Hi-Vol PM10 Air Sampler with VFC, Mechanical Timer, Brush Motor, 110V
The TE-6070V is a high-volume air sampler engineered for EPA-compliant PM10 particulate monitoring in ambient air. This configuration captures particulate matter with an aerodynamic diameter less than or equal to 10 micrometers using a size-selective inlet system designed for regulatory compliance with 40 CFR Part 50, Appendix J.
Volumetric Flow Control System
The VFC (Volumetric Flow Control) system maintains consistent sample flow rates by measuring differential pressure across the filter and automatically adjusting motor speed to compensate for filter loading. This ensures accurate volume measurements corrected to EPA reference conditions (25°C, 101.3 kPa), delivering reliable mass concentration calculations throughout the sampling period.
Key Configuration Features
- Mechanical Timer: Dependable electromechanical control for simple start/stop programming without complex digital interfaces
- Brush Motor: Field-proven motor design with replaceable carbon brushes for reliable operation in demanding outdoor environments
- 110V, 60Hz Power: Standard North American power configuration
- PM10 Size-Selective Inlet: Engineered to meet EPA performance specifications for particle size discrimination
System Applications
Designed for 24-hour PM10 mass concentration measurements up to 300 µg/std m³ in ambient air monitoring networks. The TE-6070V supports regulatory compliance monitoring for National Ambient Air Quality Standards where PM10 precision requirements are 5 µg/m³ for concentrations below 80 µg/m³. Suitable for state and local air quality agencies, industrial monitoring programs, and environmental consulting applications.
Alternative Configurations
The TE-6070 series offers multiple configurations including brushless motor versions (TE-6070VBL), digital timer options (TE-6070DV), and international power variants (TE-6070VX for 220V/50Hz, TE-6070VXZ for 220V/60Hz). PM2.5 configurations are available with the -2_5 suffix designation.
Maintenance Requirements
The PM10 sampler shall be maintained in strict accordance with manufacturer maintenance procedures. Brush motor configurations require periodic carbon brush inspection and replacement. The VFC system requires flow calibration verification using EPA-approved transfer standards to ensure measurement accuracy.
- Controller Type
- VFC
- Motor Type
- Brush
- Power Configuration
- 110volt, 60hz
- Sample Type
- PM10
- Timer Type
- Mechanical