Secure Checkout
TE-6070VFC-2_5 PM2.5 Hi-Vol Air Sampler with VFC PLUS Controller & Brush Motor, 110V

Thumbnail Filmstrip of TE-6070VFC-2_5 PM2.5 Hi-Vol Air Sampler with VFC PLUS Controller & Brush Motor, 110V Images

    Purchase TE-6070VFC-2_5 PM2.5 Hi-Vol Air Sampler with VFC PLUS Controller & Brush Motor, 110V

    TE-6070VFC-2_5 PM2.5 Hi-Vol Air Sampler with VFC PLUS Controller & Brush Motor, 110V SKU: TE-6070VFC+-2.5

    The TE-6070VFC-2_5 is a high volume air sampler engineered for EPA-compliant PM2.5 fine particulate matter sampling at 2.5 micrometers or less. This complete sampling system integrates a PM2.5 size-selective inlet with advanced VFC PLUS flow control technology and a proven brushed motor drive system for reliable field operation.

    VFC PLUS Microprocessor Control Technology

    The PLUS controller delivers precise, real-time volumetric flow control using integrated ambient temperature and barometric pressure sensors. The system determines total air volume from measured flow rate at actual ambient conditions and sampling time. Built-in auto-calibration maintains flow accuracy throughout the sampling period, while onboard data logging captures comprehensive environmental parameters including average, minimum, and maximum ambient temperature and barometric pressure along with total ambient and standard flow measurements.

    Key Specifications

    • Power Configuration: 110V, 60Hz single-phase
    • Motor Type: Brushed drive system with proven field reliability
    • Controller: VFC PLUS with microprocessor-based flow control
    • Sample Type: PM2.5 fine particulate matter
    • Timer: Digital with battery backup capability

    Data Logging and Programming Features

    The integrated digital timer provides straightforward programming for repeatable sampling periods with battery backup protection. The controller maintains four independent data logs and supports USB export for data retrieval and analysis. Multiple elapsed time indicators track sampling progress and provide operational status monitoring.

    EPA Compliance and Applications

    Designed for compliance with EPA PM2.5 monitoring requirements under 40 CFR Part 50, Appendix L, this sampler supports ambient air quality monitoring, environmental research, and institutional studies requiring fine particulate matter analysis. The measurement process is non-destructive, allowing collected PM2.5 samples to undergo subsequent physical or chemical analyses.

    Use this configuration when you need reliable, high-volume PM2.5 collection with comprehensive environmental monitoring capabilities and an easy-to-operate control package for both regulatory compliance and research applications.

    Controller Type
    VFC PLUS
    Motor Type
    Brush
    Power Configuration
    110volt, 60hz
    Sample Type
    PM2.5
    Timer Type
    Digital
    Uses PLUS tech?
    Yes