Quantitative Ashless Filter Paper - 1541-047
Gravimetric analysis demands filter paper that contributes virtually no residue after ignition, ensuring mass measurements reflect the sample alone. Tightly controlled manufacturing produces the lot-to-lot consistency that validated gravimetric methods depend on for reproducible results. For this reason, controlled manufacturing delivers the documented retention, flow rate, and physical consistency that analytical and preparative filtration methods require.
Key Filter Paper Characteristics
- Designed for gravimetric determinations where the filter paper is ashed or ignited as part of the analytical measurement step.
- Controlled fiber density balances rapid filtration with complete precipitate capture for efficient quantitative determinations.
- Rated at 22um particle retention, the fiber matrix provides a defined cutoff for consistent separation across analytical batches.
- Tightly controlled manufacturing produces documented ash content that remains consistent across production lots for method reproducibility.
- Smooth surface finish facilitates complete precipitate recovery and clean separation from the paper during transfer operations.
When your analytical procedure specifies a particular grade, the retention and purity characteristics documented above confirm method compliance. For this purpose, ashless purity positions this paper as your standard medium for any method where the filter becomes part of the final measurement. Make the decision for consistency and reliability, ensuring that your laboratory maintains its reputation for high-quality, error-free output.
- Diameter
- 47mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 541
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.006%
- Nominal Basis Weight (g/ m²)
- 82g/m²
- Pack Count
- 100
- Particle Retention
- 22um
- Pore Size (µm)
- 20.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Phosphate Gravimetry - Collects magnesium ammonium phosphate precipitate for ignition to pyrophosphate in soil and fertilizer analysis.
- Gravimetric Determination - Collects and ignites precipitates for accurate mass measurement with negligible filter blank contribution.
- Silica Determination - Captures dehydrated silica for gravimetric analysis in cement, geological, and industrial raw material testing.
- Chloride Gravimetry - Retains silver chloride precipitate for mass-based chloride determination in water quality and process control.
- Aluminum Analysis - Collects aluminum hydroxide precipitate for ignition and weighing in metallurgical and environmental methods.
- Total Ash Testing - Provides the ultra-low blank needed for accurate ash determination in food, pharmaceutical, and material samples.