Featuring high-absorbency cellulose construction delivering enhanced retention characteristics for qualitative analytical applications requiring medium-slow flow rates. 8µm pore size provides slightly more retentive performance than standard Grade 1 papers with corresponding increase in filtration time, making it ideal for applications demanding superior particulate capture and increased sample loading capacity. Extra absorbency characteristics enable soil nutrient retention in plant growth trials while maintaining reliable performance for atmospheric contaminant monitoring.
Key Cellulose Membrane Characteristics
- Enhanced absorbency compared to Grade 1 delivers superior sample retention and conveyance capabilities
- 8µm particle retention efficiently captures fine particulates while optimizing flow characteristics
- Medium flow rate provides balanced filtration speed ideal for analytical protocols requiring thorough separation
- Qualitative analytical grade construction enables material identification and determination applications
- Medium porosity structure delivers consistent performance across diverse laboratory filtration requirements
Key Construction Characteristics
- ASTM E2187-09 certified testing1 validates consistent quality and performance specifications
- Conditioned weight requirements (26.1 ± 0.5 g, SD < 0.3 g) ensure reproducible analytical results
- 150mm diameter accommodates standard laboratory funnels and filtration equipment configurations
- Hydrophilic surface chemistry promotes wetting and sample interaction for aqueous applications
- Robust cellulose construction minimizes tearing risk during filtration while maintaining compatibility with standard laboratory equipment
LE-CFP2-150 filters excel in plant growth monitoring applications where soil nutrient retention capabilities are essential for accurate agricultural research protocols. Atmospheric contaminant monitoring and soil testing applications benefit from the enhanced retention characteristics, while the medium flow rate optimizes processing time for routine analytical procedures. Each lot meets ASTM E2187-09 specifications1, ensuring validated performance consistency for your critical qualitative analysis and environmental monitoring applications requiring both superior absorbency and reliable particulate capture.
- Ahlstrom Equivalent
- 6420-1500
- Diameter
- 150mm
- Grade
- CFP2 Qualitative
- Material
- Cellulose
- MFS/Advantec Equivalent
- N023215.0CM
- Pack Count
- 100
- Pore Size (µm)
- 8
- Sartorius Equivalent
- FT-3-210-150
- Sterility
- Nonsterile
- Weight
- 1
- Wetability
- Hydrophilic
- Whatman Equivalent
- 1002-150