    CA Syringe Filters, 0.8 um, 30mm, Luer-Lok/Luer Slip, 100/Pk
    Tisch SKU: SF18287

    $119.99
    Ships in 4 weeks
     

    Tisch Scientific Cellulose Acetate (CA) Syringe Filters, 0.8 µm, 30 mm, 100/Pk - SF18287

    Tisch Scientific's sales team brings fast, courteous service to every filtration order, from first quote through fulfillment. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. The cellulose acetate membrane takes up aqueous buffers on contact while binding BSA at 3.8 micrograms per square centimeter and suits aqueous solutions, buffers, and alcohols. Polypropylene construction resists chemical degradation from routine sample matrices while pressing snugly against the membrane during the pass and preserves sample chemistry across the flow path. Where analytical results depend on clean samples, the preparation step stays consistent from sample to sample through a pre-tested syringe filter.

    Membrane Characteristics

    • Stable in aqueous saline, buffer, and protein solution matrices
    • Naturally hydrophilic surface wets readily with aqueous samples
    • Absolute-rated pores ensure the same particle cutoff every run
    • Cellulose ester backbone stable across aqueous pH range of 4 to 8
    • Smooth membrane face with even pore distribution across the active filtration area

    Housing Characteristics

    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Polypropylene density near 0.90 g/cm3 keeps housing weight low relative to denser engineering plastics
    • Impact-tolerant polypropylene body withstands routine bench handling without damage
    • Thermal-bonded construction keeps adhesives out of the fluid path

    Juggling several filter types for one routine clarification eats up your bench time. General-purpose aqueous filtration supports the sample types you handle every day so you can standardize one filter across most aqueous methods. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    11.6psi
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    30mm
    Filtration Area
    4.9cm²
    Flow Rate
    150ml
    Holdup Volume
    120µl
    Material
    Cellulose Acetate (CA)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-170μm
    Pack Count
    100
    Pore Size (µm)
    0.8
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave: 121°C for 30 minutes/ Gamma: 5kg, for 8 hours
    Volume Throughput (ml)
    110ml
    Weight
    0.91
    Wettability
    Hydrophilic
    • Protein Recovery - Maximizes yield of target proteins by minimizing nonspecific binding, preserving valuable biological samples.
    • Alcohol Compatibility - Handles low molecular weight alcohols reliably, supporting specialized chemical clarification tasks in the laboratory.
    • DNA Extraction Prep - CA's low-binding surface passes aqueous DNA extracts cleanly ahead of PCR, gel electrophoresis, and sequencing preparation.
    • Food Safety Analysis - Hydrophilic CA clarifies aqueous food extracts and beverages ahead of pesticide residue, mycotoxin, and contaminant analysis.
    • PCR Sample Prep - CA's very low non-specific binding ensures nucleic acids and buffer components pass through cleanly ahead of PCR amplification.
    • IC Sample Prep - CA membrane clarifies aqueous samples before IC injection, protecting guard columns and extending column life without analyte loss.