Chat with us, powered by LiveChat
Secure Checkout
CA Syringe Filters w/ 3 Pre-Filters, 0.22 um, 25mm, Nonsterile, 100/Pk

Thumbnail Filmstrip of CA Syringe Filters w/ 3 Pre-Filters, 0.22 um, 25mm, Nonsterile, 100/Pk Images

    Purchase CA Syringe Filters w/ 3 Pre-Filters, 0.22 um, 25mm, Nonsterile, 100/Pk

    Tisch
    CA Syringe Filters w/ 3 Pre-Filters, 0.22 um, 25mm, Nonsterile, 100/Pk SKU: SF18292

    $178.95
    Ships in 4 weeks
     

    Cellulose Acetate (CA) Syringe Filters w/ 3 Pre-Filters - SF18292

    Pharmaceutical and biotechnology laboratories demand sterile-grade filtration for biological samples carrying heavy particulate burdens that overwhelm standard single-stage membranes during routine processing operations. Triple-layer prefiltration delivers extended operational capacity for challenging matrices. Advanced 0.22µm cellulose acetate membrane construction with validated 40.6 psi bubble point and 4.08 cm² filtration area provides bacterial retention while processing medium-volume samples where dirt load capacity determines filtration success.

    Key Cellulose Acetate Membrane Characteristics

    • A 0.22 µm pore size achieves bacterial retention and sterile-grade filtration performance for cell culture media and biological samples requiring bioburden reduction
    • Hydrophilic cellulose acetate surface processes aqueous samples immediately without pre-wetting protocols, eliminating methanol exposure risks and accelerating sample preparation throughput
    • Low protein binding affinity maintains biomolecule concentrations throughout filtration, preventing adsorption losses that compromise analytical accuracy in protein-sensitive applications
    • Validated 40.6 psi bubble point ensures membrane integrity and consistent pore size distribution across production batches, supporting reproducible bacterial retention in quality-critical workflows
    • Broad aqueous buffer compatibility supports biological and pharmaceutical applications without membrane degradation, though aggressive organic solvents require alternative membrane chemistries

    Key Construction Characteristics

    • Triple prefilter configuration with two glass fiber layers plus polypropylene stage captures gross particulates upstream of the membrane, dramatically extending operational life
    • A 400 µL holdup volume balances sample recovery with filtration capacity in medium-volume applications, preserving material while accommodating the triple prefilter system's additional internal volume
    • Durable polypropylene housing withstands operating pressures to 87 psi and temperatures to 60°C, supporting diverse processing conditions across manual and vacuum-assisted filtration configurations
    • Luer-Lok and Luer Slip connections provide universal syringe compatibility, integrating seamlessly into existing laboratory workflows without requiring specialized adapters or connection modifications

    When your laboratory processes particulate-rich biological samples requiring sterile-grade filtration, single-stage membranes clog rapidly and force costly filter replacements. The 25mm platform with triple prefilter protection and 4.08 cm² cellulose acetate membrane processes up to 50 mL throughput per device. Such a configuration delivers the operational capacity your workflows demand, enabling you to complete sample batches without interruption while maintaining sterile filtration performance critical for biological and pharmaceutical applications.

    For more information about chemical and material compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    40.6psi
    Connection Type
    Luer-Lok/ Luer Slip
    Construction
    PP
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    32ml
    Holdup Volume
    400µl
    Material
    Cellulose Acetate (CA)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-170μm
    Pack Count
    100
    Pore Size (µm)
    0.22
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    GF+GF+PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave: 121°C for 30 minutes/ Gamma: 5kg, for 8 hours
    Volume Throughput (ml)
    50ml
    Weight
    0.52
    Wetability
    Hydrophilic
    • Cell Culture Media Sterilization - Removes bacteria from culture media and serum supplements, ensuring sterile conditions for sensitive cell lines
    • Biological Sample Clarification - Filters particulate-laden lysates and tissue homogenates before analysis, protecting downstream instrumentation
    • Pharmaceutical Buffer Preparation - Clarifies formulation buffers and reagent solutions for aseptic processing, meeting strict quality requirements
    • Environmental Water Testing - Prepares turbid water samples for microbial analysis, removing gross particulates without compromising recovery
    • Protein Solution Filtration - Clarifies antibody preparations with minimal adsorption, removing aggregates and bioburden before purification
    • HPLC Sample Preparation - Protects analytical columns from particulate fouling in complex biological matrices, extending equipment life