Tisch Scientific Cellulose Acetate (CA) Syringe Filters, 1.2 µm, 30 mm, 100/Pk - SF18326
Tisch Scientific reduces per-unit costs for laboratories that place blanket purchase agreements or large-quantity orders. Because each syringe filter is dedicated to one sample, a failed or contaminated filtration stays isolated to its own analyst's run and leaves the next analyst's queue clear. Cellulose acetate admits water-based reagents immediately, with no surfactant step while maintaining a hydrated barrier ahead of any protein contact and maintains a particle cutoff at that rating. Low-extractable polypropylene keeps sample purity intact through the filtration pass while maintaining a low-dead-volume internal flow path and holds its seal true run after run. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.
Membrane Characteristics
- Tolerates methanol and ethanol at typical laboratory working concentrations
- Retains particles at the membrane surface instead of throughout its thickness
- Biologically nontoxic cellulose ester provides a clean filtration surface
- Dilute samples retain their true, unadsorbed concentration through the membrane
- Cellulose acetate's open pore structure supports high flow rates at low operating pressure
Housing Characteristics
- Impact-tolerant polypropylene body withstands routine bench handling without damage
- Plasticizer-free polyolefin construction keeps the fluid path clean
- Minimal extractable release from the housing supports sensitive analytical work downstream
- Rigid polypropylene body maintains its geometry through routine filtration pressure
A particulate-laden aqueous sample makes the rest of your preparation unpredictable. General-purpose aqueous filtration supports the sample types you handle every day so you can standardize one filter across most aqueous methods. Standardize your filtration purchases across every method with volume pricing and documentation from the Tisch Scientific team.
Sterilization Guidance
Factory sterilization supports immediate use in workflows where sterility assurance matters.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Bubble Point (psi)
- 5.8psi
- Connection Type
- Luer-Lok/Luer Slip
- Construction
- PP
- Diameter
- 30mm
- Filtration Area
- 4.9cm²
- Flow Rate
- 180ml
- Holdup Volume
- 120µl
- Material
- Cellulose Acetate (CA)
- Maximum Operating Pressure
- 87psi
- Maximum Operating Temperature (°C)
- 60°C
- Membrane Thickness (µm)
- 80-170μm
- Pack Count
- 100
- Pore Size (µm)
- 1.2
- Prefilter (Yes/No)
- Yes
- Prefilter Material
- PP
- Sterility
- Sterile
- Volume Throughput (ml)
- 110ml
- Weight
- 1.40
- Wettability
- Hydrophilic
- Temperature Stability - Maintains integrity across normal lab bench temperatures for consistent, dependable filtration performance.
- Urinalysis Prep - CA clarifies urine samples by removing particulates ahead of automated urinalysis without altering biochemical composition.
- Allergen Testing Prep - CA's low-binding surface cleanly passes allergen proteins from aqueous food extracts ahead of ELISA allergen quantitation.
- PCR Sample Prep - CA's very low non-specific binding ensures nucleic acids and buffer components pass through cleanly ahead of PCR amplification.
- Amino Acid Analysis - Hydrophilic CA clarifies amino acid standards and digest samples for HPLC or ion chromatography quantitation of food and feeds.
- Saline Solution Prep - CA membrane filters saline and physiological buffer solutions, removing particulates for in vitro assays and formulation use.