CA Syringe Filter, 0.45um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of CA Syringe Filter, 0.45um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase CA Syringe Filter, 0.45um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    CA Syringe Filter, 0.45um, 13mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF14486

    $88.95
    In Stock
     

    Tisch Scientific Cellulose Acetate (CA) Syringe Filters, 0.45 µm, 13 mm, 100/Pk - SF14486

    Tisch Scientific reduces per-unit costs for laboratories that place blanket purchase agreements or large-quantity orders. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. Cellulose acetate binds BSA at 3.8 micrograms per square centimeter while stripping fine particulates above its designated micron threshold and stays smooth with low extractable background. The polypropylene housing holds its seal true run after run and preserves sample chemistry across the flow path. For routine sample preparation across many methods, each analytical run starts with a consistent, particle-free sample without added hardware or a cleaning step.

    Membrane Characteristics

    • Cellulose ester backbone stable across aqueous pH range of 4 to 8
    • Retains particles at the membrane surface instead of throughout its thickness
    • Biologically nontoxic cellulose ester provides a clean filtration surface
    • Native surface hydroxyl groups sustain a hydration layer ahead of protein contact
    • Cellulose acetate's open pore structure supports high flow rates at low operating pressure

    Housing Characteristics

    • Stable across the full aqueous pH range in routine sample work
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion

    Juggling several filter types for one routine clarification eats up your bench time. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    23.2psi
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    13mm
    Filtration Area
    1.09cm²
    Flow Rate
    16ml
    Holdup Volume
    20µl
    Material
    Cellulose Acetate (CA)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-170μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave: 121°C for 30 minutes/ Gamma: 5kg, for 8 hours
    Volume Throughput (ml)
    10ml
    Weight
    0.19
    Wettability
    Hydrophilic
    • Temperature Stability - Maintains integrity across normal lab bench temperatures for consistent, dependable filtration performance.
    • Ophthalmic Formulation Prep - Low-extractable CA filters ophthalmic solutions ahead of quality testing and release without contributing contaminants.
    • Serum Protein Analysis - Low-binding CA ensures serum proteins pass through without adsorption, preserving sample integrity for immunoassay panels.
    • PCR Sample Prep - CA's very low non-specific binding ensures nucleic acids and buffer components pass through cleanly ahead of PCR amplification.
    • Low-Volume Sample Prep - CA syringe filters process precious microliter samples with minimal hold-up volume, maximizing recovery of dilute analytes.
    • Groundwater Analysis - Separates the dissolved fraction of environmental water samples ahead of trace metal analysis by ICP-MS or ICP-OES.