CA Syringe Filter, 0.45um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of CA Syringe Filter, 0.45um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase CA Syringe Filter, 0.45um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    CA Syringe Filter, 0.45um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF14488

    $109.99
    In Stock
     

    Tisch Scientific Cellulose Acetate (CA) Syringe Filters, 0.45 µm, 25 mm, 100/Pk - SF14488

    Tisch Scientific's representatives greet every caller with patience, whatever brings them to the phone. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. Cellulose acetate handles water-based samples and low-alcohol solutions while stripping fine particulates above its designated micron threshold and keeps filtrate clean ahead of analysis. Polypropylene construction maintains a low-dead-volume internal flow path while leaving no seam for sample to bypass the membrane and preserves sample chemistry across the flow path. When method reproducibility rests on consistent sample prep, syringe filtration holds that standard injection after injection.

    Membrane Characteristics

    • Cellulose ester backbone stable across aqueous pH range of 4 to 8
    • BSA adsorption near 3.8 micrograms per square centimeter across the membrane
    • Naturally hydrophilic surface wets readily with aqueous samples
    • No alcohol pre-wetting required before aqueous sample introduction
    • Smooth membrane face with even pore distribution across the active filtration area

    Housing Characteristics

    • Stable across the full aqueous pH range in routine sample work
    • Optimized internal geometry minimizes backpressure in service
    • Plasticizer-free polyolefin construction keeps the fluid path clean
    • Rigid polypropylene body maintains its geometry through routine filtration pressure

    A particulate-laden aqueous sample makes the rest of your preparation unpredictable. Consistent aqueous clarification clears particulates without slowing your bench routine from the first sample of the day through the last. Request a quality certificate, lot documentation, or a blanket-order quote for your filtration order at any time.

    Sterilization Guidance

    Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    23.2psi
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    64ml
    Holdup Volume
    100µl
    Incompatibility
    Acids, dichloromethane, sodium hydroxide, ketones
    Material
    Cellulose Acetate (CA)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-170μm
    Pack Count
    100
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave: 121°C for 30 minutes/ Gamma: 5kg, for 8 hours
    Volume Throughput (ml)
    50ml
    Weight
    0.52
    Wettability
    Hydrophilic
    • Ophthalmic Formulation Prep - Low-extractable CA filters ophthalmic solutions ahead of quality testing and release without contributing contaminants.
    • Pharma Buffer Filtration - Low-extractable CA filters pharmaceutical-grade aqueous buffers ahead of formulation and biological assay applications.
    • Vaccine and Plasma Processing - Staged 0.45 micron prefiltration reduces bioburden ahead of a final 0.2 micron sterilizing stage.
    • Stability Testing Prep - Hydrophilic CA membrane clarifies stability samples without analyte loss, supporting accurate potency tracking over time.
    • Allergen Testing Prep - CA's low-binding surface cleanly passes allergen proteins from aqueous food extracts ahead of ELISA allergen quantitation.
    • Serum Protein Analysis - Low-binding CA ensures serum proteins pass through without adsorption, preserving sample integrity for immunoassay panels.