Chat with us, powered by LiveChat

Secure Checkout
CA Syringe Filter, 0.45um, 4 mm, Luer-Lok/Luer Slip, Nonsterile, 200 Pk

Thumbnail Filmstrip of CA Syringe Filter, 0.45um, 4 mm, Luer-Lok/Luer Slip, Nonsterile, 200 Pk Images

    Purchase CA Syringe Filter, 0.45um, 4 mm, Luer-Lok/Luer Slip, Nonsterile, 200 Pk

    CA Syringe Filter, 0.45um, 4 mm, Luer-Lok/Luer Slip, Nonsterile, 200 Pk
    Tisch SKU: SF17509

    $193.99
    2 in stock. Additional units ship in 4 weeks.
     

    Tisch Scientific Cellulose Acetate (CA) Syringe Filters, 0.45 µm, 4 mm, 200/Pk - SF17509

    Tisch Scientific vets its filtration partners carefully, favoring those with a consistent record of dependable output. Individually packaged and pre-tested, a syringe filter needs no functional check before use the way a shared reusable holder does. Low-extractable cellulose acetate keeps filtrate clean ahead of analysis while admitting water-based reagents immediately, with no surfactant step and suits aqueous solutions, buffers, and alcohols. Polypropylene construction resists chemical degradation from routine sample matrices while sustaining efficient flow on viscous samples and presses snugly against the membrane during the pass. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.

    Membrane Characteristics

    • BSA adsorption near 3.8 micrograms per square centimeter across the membrane
    • Dilute samples retain their true, unadsorbed concentration through the membrane
    • Native surface hydroxyl groups sustain a hydration layer ahead of protein contact
    • Cellulose acetate's open pore structure supports high flow rates at low operating pressure
    • Stable in aqueous saline, buffer, and protein solution matrices

    Housing Characteristics

    • Housing rated for reliable filtration under syringe-applied backpressure at its maximum operating pressure
    • Withstands standard 121°C steam autoclave cycles without softening or structural distortion
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Rigid polypropylene body maintains its geometry through routine filtration pressure

    Particulates in your buffers, reagents, and aqueous samples slow your preparation and throw off its consistency. Consistent aqueous clarification clears particulates without slowing your bench routine the same way every time you run it. Contact Tisch Scientific for a quote, lead time, or stock-on-hand check on your filtration product selection.

    Sterilization Guidance

    The housing supports customer autoclave sterilization at 121°C for 30 minutes.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    23.2psi
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    4mm
    Filtration Area
    0.125cm²
    Flow Rate
    2ml
    Holdup Volume
    1µl
    Material
    Cellulose Acetate (CA)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-170μm
    Pack Count
    200
    Pore Size (µm)
    0.45
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave: 121°C for 30 minutes/ Gamma: 5kg, for 8 hours
    Volume Throughput (ml)
    1ml
    Weight
    0.24
    Wettability
    Hydrophilic
    • Vaccine and Plasma Processing - Staged 0.45 micron prefiltration reduces bioburden ahead of a final 0.2 micron sterilizing stage.
    • Alcohol Compatibility - Handles low molecular weight alcohols reliably, supporting specialized chemical clarification tasks in the laboratory.
    • Serum Protein Analysis - Low-binding CA ensures serum proteins pass through without adsorption, preserving sample integrity for immunoassay panels.
    • DNA Extraction Prep - CA's low-binding surface passes aqueous DNA extracts cleanly ahead of PCR, gel electrophoresis, and sequencing preparation.
    • LC-MS Sample Prep - CA's low-binding surface preserves small molecule and peptide analytes from adsorption during aqueous preparation for LC-MS runs.
    • Groundwater Analysis - Separates the dissolved fraction of environmental water samples ahead of trace metal analysis by ICP-MS or ICP-OES.