CA Syringe Filter, 0.8um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

Thumbnail Filmstrip of CA Syringe Filter, 0.8um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk Images

    Purchase CA Syringe Filter, 0.8um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk

    CA Syringe Filter, 0.8um, 25mm, Luer-Lok/Luer Slip, Nonsterile, 100/Pk
    Tisch SKU: SF18277

    $118.95
    In Stock
     

    Tisch Scientific Cellulose Acetate (CA) Syringe Filters, 0.8 µm, 25 mm, 100/Pk - SF18277

    Tisch Scientific holds its filtration pricing at levels that let budget-conscious laboratories stretch procurement dollars further. A syringe filter dispenses filtrate directly into an autosampler vial, without the intermediate collection vessel a bulk vacuum filtration setup typically needs. Cellulose acetate handles water-based samples and low-alcohol solutions and takes up aqueous buffers on contact. The polypropylene housing resists aqueous acids, bases, and alcohols in routine use and sheds virtually no extractable material into the sample. Where bench-scale prep must move quickly from one sample to the next, each sample starts as clean as the last without a carry-over risk or a cleaning step between uses.

    Membrane Characteristics

    • Tolerates methanol and ethanol at typical laboratory working concentrations
    • No alcohol pre-wetting required before aqueous sample introduction
    • Native surface hydroxyl groups sustain a hydration layer ahead of protein contact
    • Biologically nontoxic cellulose ester provides a clean filtration surface
    • Retains particles at the membrane surface instead of throughout its thickness

    Housing Characteristics

    • Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
    • Minimal extractable release from the housing supports sensitive analytical work downstream
    • Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
    • Inert polyolefin wall contributes minimal sample adsorption to the filtrate

    Juggling several filter types for one routine clarification eats up your bench time. General-purpose aqueous filtration supports the sample types you handle every day so you can standardize one filter across most aqueous methods. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.

    Sterilization Guidance

    Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.

    For more information about chemical compatibility, please review our Chemical Compatibility Chart.

    Bubble Point (psi)
    11.6psi
    Burst Pressure (psi)
    87psi.
    Connection Type
    Luer-Lok/Luer Slip
    Construction
    PP
    Diameter
    25mm
    Filtration Area
    4.08cm²
    Flow Rate
    130ml
    Holdup Volume
    100µl
    Incompatibility
    Acids, dichloromethane, sodium hydroxide, ketones
    Material
    Cellulose Acetate (CA)
    Maximum Operating Pressure
    87psi
    Maximum Operating Temperature (°C)
    60°C
    Membrane Thickness (µm)
    80-170μm
    Pack Count
    100
    Pore Size (µm)
    0.8
    Prefilter (Yes/No)
    Yes
    Prefilter Material
    PP
    Sterility
    Nonsterile
    Sterilization
    Autoclave: 121°C for 30 minutes/ Gamma: 5kg, for 8 hours
    Volume Throughput (ml)
    50ml
    Weight
    0.52
    Wettability
    Hydrophilic
    • Urinalysis Prep - CA clarifies urine samples by removing particulates ahead of automated urinalysis without altering biochemical composition.
    • Alcohol Compatibility - Handles low molecular weight alcohols reliably, supporting specialized chemical clarification tasks in the laboratory.
    • Low-Volume Sample Prep - CA syringe filters process precious microliter samples with minimal hold-up volume, maximizing recovery of dilute analytes.
    • Aqueous Sample Prep - CA membrane clarifies water-based samples quickly without pre-wetting, protecting downstream instruments from particle fouling.
    • Temperature Stability - Maintains integrity across normal lab bench temperatures for consistent, dependable filtration performance.
    • Ophthalmic Formulation Prep - Low-extractable CA filters ophthalmic solutions ahead of quality testing and release without contributing contaminants.