Foxx EZFlow PVDF Syringe Filters, 0.22 µm, 25 mm, 100/Pk - 37P-2216-OEM
Foxx Life Sciences offers its EZFlow and EZlabpure syringe filters in both sterile and nonsterile formats, matching the format to routine sample preparation or aseptic filtration needs. A sterilizing-grade syringe filter carries manufacturer bacterial retention testing built into the design, giving analysts documented sterile-grade performance without repeating that testing in-house for the format. PVDF provides sterilizing-grade retention at the rated sub-micron pore size and resists HPLC mobile phases, alcohols, and mild hydrocarbons. Polypropylene construction maintains a low-dead-volume internal flow path while standing firm against aqueous acids, bases, and alcohols during regular handling and sheds virtually no extractable material into the sample. Where bacterial contamination must stay out of the sample, manufacturer-tested retention keeps the instrument and downstream assay protected without a housing to maintain or clean.
Prefiltration
- High dirt-holding capacity suits very turbid, high-solids sample loads
- Naturally hydrophilic borosilicate fiber wets quickly with aqueous samples
- Depth-loading glass fiber matrix captures particulate throughout its full thickness
- Two-stage construction pairs a borosilicate glass fiber prefilter with the downstream membrane
Membrane Characteristics
- Ethylene oxide sterilization cycles leave pore integrity and flow performance intact
- Mechanically durable membrane holds integrity under filtration pressure
- Hydrochloric, dilute nitric, and up to 90% sulfuric acid cause no attack
- Low extractables preserve a clean chromatographic baseline
- Limiting oxygen index runs high, supporting flame resistance and low smoke
Housing Characteristics
- Minimal ionic background from the polypropylene housing supports ion chromatography and trace-metal ICP-MS sample preparation
- Burst pressure rating provides a wide safety margin above the rated maximum operating pressure
- Withstands standard 121°C steam autoclave cycles without softening or structural distortion
- Thermal-bonded construction keeps adhesives out of the fluid path
Particulates in your buffers and mobile phases shorten column life and unsettle your baselines. Reliable particulate removal protects your instruments and your data across reagent, buffer, and mobile-phase preparation. Request details on payment terms or standing-order arrangements for your routine filtration purchases.
Sterilization Guidance
Standard autoclave cycles at 121°C for 30 minutes prepare the device for sterile workflows.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Material
- PVDF+GF Membrane
- Pack Count
- 100
- Sterility
- Nonsterile
- Biological Samples - Clarifies protein-rich solutions without loss of target molecules, preserving sample integrity for critical downstream assays.
- IC Guard Filtration - Removes particulates from aqueous samples before ion analysis, keeping detector cells free of fouling between injections.
- Protein Purification - Facilitates routine clarification of chromatography samples, preventing column fouling without binding target proteins.
- Pharmaceutical QC - Supports routine quality control testing by reliably filtering mild organic solvent mixtures and drug formulations daily.
- Microbiome Sampling - Concentrates waterborne microbial cells on a low-binding membrane ahead of DNA extraction and metagenomics sequencing.
- Forensic Toxicology Screening - Clarifies urine samples ahead of LC-MS drug screening, supporting reliable detection of abused drugs and metabolites.