Foxx EZFlow PTFE Syringe Filters, 0.22 µm, 33 mm, 100/Pk - 386-2416-OEM
Foxx Life Sciences produces its EZFlow and EZlabpure syringe filters as single-use devices under ISO quality system controls, supporting consistent membrane performance from lot to lot. A sterilizing-grade syringe filter delivers point-of-use sterile filtration in a single-use format, without the housing and gasket maintenance a reusable stainless steel filter holder requires. PTFE stays chemically inert against aggressive solvents, strong acids, and alkalis in service and combines aqueous wetting with broad solvent resistance. The polypropylene housing resists aqueous acids, bases, and alcohols in routine use while pressing snugly against the membrane during the pass and preserves sample chemistry across the flow path. For workflows requiring validated sterile-grade performance, point-of-use retention meets it without a separate sterilization step.
Membrane Characteristics
- Solvent tolerance includes full-strength tetrahydrofuran and chlorinated solvents such as dichloromethane
- Absolute pore rating delivers reproducible retention across every protocol
- Fully fluorinated carbon backbone resists ultraviolet and ozone degradation
- High membrane porosity, 70 to 80 percent void volume, delivers high flow at low pressure
- Validated against a liquid suspension Brevundimonas diminuta challenge at 10 million CFU per square centimeter
Housing Characteristics
- Optimized internal geometry minimizes backpressure in service
- Resists stress cracking from aqueous salt and buffer solutions
- Minimal extractable release from the housing supports sensitive analytical work downstream
- Inert polyolefin wall contributes minimal sample adsorption to the filtrate
A column clogging mid-run from unfiltered sample can cost you the rest of your analytical day. Pre-injection filtration protects the resolution your methods depend on by clearing particulates ahead of the column and frits. Start a live chat with the Tisch Scientific team about packaging, unit count, and ship-date for your filtration order.
Sterilization Guidance
Customer autoclave compatibility at 121°C accommodates in-lab sterilization timing.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Material
- PTFE Membrane
- Pack Count
- 100
- Sterility
- Nonsterile
- Chemical Synthesis - Resists aggressive organic solvents and corrosive acids for compatibility with harsh synthetic reaction mixtures.
- Dye and Pigment Analysis - Clarifies dye solutions in DMF, NMP, and other aggressive organics ahead of spectrophotometric color strength testing.
- Extractables Testing - Clarifies packaging material organic solvent extracts ahead of LC-MS analysis, keeping background low for leachable detection.
- Polymer GPC Prep - Clarifies polymer solutions in THF ahead of gel permeation chromatography, protecting columns from particulates.
- Battery Electrolyte Prep - Clarifies lithium-ion battery electrolyte in carbonate solvents ahead of GC-MS purity and impurity analysis.
- Spirits Congener Analysis - Clarifies distilled spirits samples ahead of GC analysis, protecting columns from residue during congener profiling.