Foxx EZlabpure Nylon Syringe Filters, 0.45 µm, 13 mm, 100/Pk - 744-3116-FLS
Foxx Life Sciences produces its EZFlow and EZlabpure syringe filters as single-use devices under ISO quality system controls, supporting consistent membrane performance from lot to lot. Syringe filters replace the separate holder and vacuum apparatus of bulk filtration with a single disposable unit, eliminating cleaning between samples. The nylon membrane holds dimensional stability under rated backpressure while stopping particulates too coarse to pass its pore opening and accepts water-based samples without surfactant conditioning. Polyolefin construction sheds virtually no extractable material into the sample while pressing snugly against the membrane during the pass and maintains a low-dead-volume internal flow path. Where analytical results depend on clean samples, the preparation step stays consistent from sample to sample through a pre-tested syringe filter.
Membrane Characteristics
- Moisture-plasticized amide linkages raise membrane impact toughness over dry resin
- Non-sterile format suits HPLC and GC sample clarification
- Filtration clarifies HPLC mobile phase buffers of particulates
- Autoclaving at 121°C for 30 minutes leaves pore structure intact
- Low extractable contribution to sensitive analytical preparations
Housing Characteristics
- Rigid polypropylene body maintains its geometry through routine filtration pressure
- Polypropylene housing tolerates dilute aqueous acids, bases, and alcohols used in routine sample prep
- The seal formed against the membrane blocks bypass at rated operating pressure
- Minimal intrinsic autofluorescence from the polypropylene housing supports background-sensitive fluorescence-based assay work downstream
Juggling several filter types for one routine clarification eats up your bench time. General-purpose aqueous filtration supports the sample types you handle every day across your water-analysis and general analytical workflows. Request blanket-order pricing and paperwork support for your routine filtration purchases.
Sterilization Guidance
The housing supports customer autoclave sterilization at 121°C for 30 minutes.
For more information about chemical compatibility, please review our Chemical Compatibility Chart.
- Material
- Nylon membrane
- Pack Count
- 100
- Sterility
- Nonsterile
- GC Sample Prep - Clarifies aqueous and organic extracts ahead of gas chromatography injection, protecting inlets from particulate fouling.
- Dissolution Testing - Supports accurate drug release profiles by clarifying dissolution samples ahead of HPLC quantitation in QC labs.
- Column Protection - Extends the life of analytical columns by reliably removing micro-particulates from aqueous mobile phases in HPLC.
- Solvent Filtering - Supports clarification of ester-based and alcohol solvents with precision during routine laboratory sample processing.
- Drinking Water Analysis - Clarifies tap and source water samples ahead of metals, nitrate, and trace-contaminant compliance testing.
- Buffer Filtration - Delivers high mechanical strength for efficient clarification of alkaline buffers and aqueous reagents in the lab.