Qualitative Filter Paper - Grade 595, 500mm, 100/pk - 10311656
Whatman's name appears throughout published laboratory literature, a track record that keeps its products cited in documented analytical methods. The qualitative grade sits at the routine end of the filter paper lineup, priced for everyday laboratory use. The cellulose sheet handles easily through folding, seating, and transfer steps while capturing particulates across routine gravity and vacuum filtration and keeps chemical background low for general methods. When a method calls for nominal retention at a known grade, the separation standard stays reproducible across every run without a premium cellulose option.
Filter Paper Characteristics
- Sheet thickness in the 140 to 210 micrometer range
- Nominal retention of 7 microns and below for fine precipitates and cloudy suspensions
- Pure cellulose construction for routine gravity and vacuum filtration
- Neutral, chemically untreated surface for general sample preparation
- Hot filtration compatible for clarifying solutions near boiling
- Fast flow rate accelerates clarification of large sample volumes
Juggling several filter types for one routine clarification eats up your bench time. General-purpose aqueous filtration supports the sample types you handle every day so you can standardize one filter across most aqueous methods. Send your order details to the Tisch Scientific team for a quote.
- Diameter
- 500mm
- Flow Speed
- Medium Fast
- Folded/ Fluted/ Pleated
- Yes
- Grade
- 595
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Basis Weight (g/ m²)
- 68g/m²
- Particle Retention
- 4-7um
- Pore Size (µm)
- 4.0-7.0
- Qualitative/ Quantitative
- Qualitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Teaching Laboratories - Provides economical, reliable filtration for student experiments and routine instructional separation exercises.
- Food and Beverage QC - Clarifies juices, wines, and food extracts to remove pulp and debris before quality-control analysis steps.
- Antibiotic Susceptibility Testing - Supports antimicrobial-impregnated discs for Kirby-Bauer testing of bacterial cultures.
- Routine Separations - Separates precipitates and solids from liquids in everyday qualitative laboratory filtration workflows daily.
- Sample Clarification - Removes coarse particulates from solutions ahead of analysis, protecting instruments and improving sample clarity.
- Chemical Indicator Testing - Changes color on contact with compounds like hydrogen sulfide gas when impregnated with reagents such as lead acetate.