Quantitative Filter Paper - Grade 40, 110mm, 500/pk - 10380004
Whatman's name appears throughout published laboratory literature, a track record that keeps its products cited in documented analytical methods. Grade 40 serves as the industry-standard ashless grade for soil analysis and AA spectrophotometry cleanup steps. Ashless cellulose construction keeps chemical background low for critical gravimetric methods while retaining particulates at a fine, gravimetric-grade cutoff and seats cleanly in funnels for gravimetric filtration steps. When a gravimetric determination depends on the filter itself adding no measurable mass, the ashless grade's controlled ash ceiling keeps that determination valid.
Filter Paper Characteristics
- Ignites completely on combustion
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Nominal thickness between 165 and 220 micrometers
- Compatible with hot filtration in gravimetric workflows
- Medium flow rate balances retention and throughput for routine ashless filtration
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
A filter that contributes mass of its own puts a blank correction between you and the analyte you set out to weigh. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue as the crucible comes to constant weight. Request a quality certificate or lot documentation on your order from our support team, any time.
- Diameter
- 110mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- Yes
- Grade
- 40
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 95g/m²
- Pack Count
- 500
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- AA Spectrophotometry Prep - Filters soil digests ahead of atomic absorption spectrophotometry, keeping Grade 40 ashless background low.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.