Quantitative Filter Paper - Grade 40, 150mm, 500/pk - 10380006
Whatman's name appears throughout published laboratory literature, a track record that keeps its products cited in documented analytical methods. Ashless grade filter paper anchors gravimetric analysis workflows in pharma, biotech, and environmental laboratories. Ashless cellulose construction keeps chemical background low for critical gravimetric methods and handles routine soil-analysis and spectrophotometry cleanup filtration steps. Where trace-metal contamination would compromise a digestion or spectrophotometry step, Grade 40's ashless retention keeps results clean.
Filter Paper Characteristics
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Basis weight between 75 and 96 grams per square meter
- Medium flow rate balances retention and throughput for routine ashless filtration
- Ash content held to a 0.007 percent maximum
- Leaves negligible carbon residue
- Adds no measurable mass to a gravimetric determination
A filter that contributes mass of its own puts a blank correction between you and the analyte you set out to weigh. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. Request blanket-order pricing for your routine laboratory orders from the Tisch Scientific team.
- Diameter
- 150mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- Yes
- Grade
- 40
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 95g/m²
- Pack Count
- 500
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- AA Spectrophotometry Prep - Filters soil digests ahead of atomic absorption spectrophotometry, keeping Grade 40 ashless background low.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.