Quantitative Filter Paper - Grade 40, 12.7mm, 400/pk - 1440-012
Lot-to-lot consistency and complete documentation trace back to Whatman's long-standing manufacturing platform, meeting what analytical laboratories expect as standard. Grade 40 serves as the industry-standard ashless grade for soil analysis and AA spectrophotometry cleanup steps. Ashless grade paper seats cleanly in funnels for gravimetric filtration steps while controlling ash content to a strict 0.007 percent maximum after ignition and keeps chemical background low for critical gravimetric methods. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Basis weight between 75 and 96 grams per square meter
- Ignites completely on combustion
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Ash content held to a 0.007 percent maximum
- Compatible with hot filtration in gravimetric workflows
- Leaves negligible carbon residue
A filter that contributes mass of its own puts a blank correction between you and the analyte you set out to weigh. A clarified acid digest carries only the dissolved fraction to your instrument across the strong-acid matrices your digestion method runs. For a fast answer on order status or stock availability, start a live chat with the Tisch Scientific team.
- Diameter
- 12.7mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Grade
- 40
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 95g/m²
- Pack Count
- 400
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- AA Spectrophotometry Prep - Filters soil digests ahead of atomic absorption spectrophotometry, keeping Grade 40 ashless background low.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.