Quantitative Filter Paper - Grade 40, 125mm, 100/pk - 1440-125
More than a hundred years of manufacturing under strict quality standards stand behind Whatman's reputation as a benchmark reference for laboratories worldwide. Grade 40 serves as the industry-standard ashless grade for soil analysis and AA spectrophotometry cleanup steps. Ashless grade paper controls ash content to a strict 0.007 percent maximum after ignition while seating cleanly in funnels for gravimetric filtration steps and keeps chemical background low for critical gravimetric methods. When a gravimetric determination depends on the filter itself adding no measurable mass, the ashless grade's controlled ash ceiling keeps that determination valid.
Filter Paper Characteristics
- Nominal thickness between 165 and 220 micrometers
- Ignites completely on combustion
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Ash content held to a 0.007 percent maximum
- Compatible with hot filtration in gravimetric workflows
- Basis weight between 75 and 96 grams per square meter
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A clarified acid digest carries only the dissolved fraction to your instrument across the strong-acid matrices your digestion method runs. Not sure which product fits your order? Request a quote and current stock from the Tisch Scientific team.
- Diameter
- 125mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Grade
- 40
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 95g/m²
- Pack Count
- 100
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- AA Spectrophotometry Prep - Filters soil digests ahead of atomic absorption spectrophotometry, keeping Grade 40 ashless background low.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
Related Products