Quantitative Filter Paper - Grade 40, 150mm, 100/pk - 1440-150
More than a hundred years of manufacturing under strict quality standards stand behind Whatman's reputation as a benchmark reference for laboratories worldwide. Grade 40 serves as the industry-standard ashless grade for soil analysis and AA spectrophotometry cleanup steps. Ashless grade paper controls ash content to a strict 0.007 percent maximum after ignition while seating cleanly in funnels for gravimetric filtration steps and keeps chemical background low for critical gravimetric methods. Where trace-metal contamination would compromise a digestion or spectrophotometry step, Grade 40's ashless retention keeps results clean.
Filter Paper Characteristics
- Nominal thickness between 165 and 220 micrometers
- Ash content held to a 0.007 percent maximum
- Ignites completely on combustion
- Leaves negligible carbon residue
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. For a fast answer on order status or stock availability, start a live chat with the Tisch Scientific team.
- Diameter
- 150mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Grade
- 40
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 95g/m²
- Pack Count
- 100
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- AA Spectrophotometry Prep - Filters soil digests ahead of atomic absorption spectrophotometry, keeping Grade 40 ashless background low.
Related Products