Quantitative Filter Paper - Grade 40, 185mm, 100/pk - 1440-185
Whatman now operates as part of Cytiva's life sciences business, gaining a parent company whose manufacturing discipline extends across the bench, the field, and the production floor. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. Ashless cellulose construction keeps chemical background low for critical gravimetric methods and seats cleanly in funnels for gravimetric filtration steps. When a gravimetric determination depends on the filter itself adding no measurable mass, the ashless grade's controlled ash ceiling keeps that determination valid.
Filter Paper Characteristics
- Nominal thickness between 165 and 220 micrometers
- Compatible with hot filtration in gravimetric workflows
- Basis weight between 75 and 96 grams per square meter
- Ash content held to a 0.007 percent maximum
- Adds no measurable mass to a gravimetric determination
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. Request blanket-order pricing for your routine laboratory orders from the Tisch Scientific team.
- Diameter
- 185mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Grade
- 40
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 95g/m²
- Pack Count
- 100
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- AA Spectrophotometry Prep - Filters soil digests ahead of atomic absorption spectrophotometry, keeping Grade 40 ashless background low.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
Related Products