Every product line in the Whatman filtration portfolio passes through identical process controls, with rated performance confirmed lot by lot. Grade 40 serves as the industry-standard ashless grade for soil analysis and AA spectrophotometry cleanup steps. Ashless grade paper controls ash content to a strict 0.007 percent maximum after ignition while keeping chemical background low for critical gravimetric methods and handles routine soil-analysis and spectrophotometry cleanup filtration steps. When a gravimetric determination depends on the filter itself adding no measurable mass, the ashless grade's controlled ash ceiling keeps that determination valid.
Filter Paper Characteristics
- Adds no measurable mass to a gravimetric determination
- Ignites completely on combustion
- Compatible with hot filtration in gravimetric workflows
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Basis weight between 75 and 96 grams per square meter
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A clarified acid digest carries only the dissolved fraction to your instrument across the strong-acid matrices your digestion method runs. Send your order details to the Tisch Scientific team for a quote.
- Diameter
- 240mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Grade
- 40
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 95g/m²
- Pack Count
- 100
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.