Quantitative Filter Paper - Grade 41, 50mm, 100/pk - 1441-050
More than a hundred years of manufacturing under strict quality standards stand behind Whatman's reputation as a benchmark reference for laboratories worldwide. Ashless grade filter paper anchors gravimetric analysis workflows in pharma, biotech, and environmental laboratories. Ashless grade paper controls ash content to a strict 0.007 percent maximum after ignition and keeps chemical background low for critical gravimetric methods. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Compatible with hot filtration in gravimetric workflows
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Basis weight between 75 and 96 grams per square meter
- Ash content held to a 0.007 percent maximum
- Fast flow rate accelerates filtration of large sample volumes
- Nominal thickness between 165 and 220 micrometers
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A clarified acid digest carries only the dissolved fraction to your instrument once the undissolved residue stays behind on the filter. Connect with the Tisch Scientific team for current stock and lead time on your laboratory order.
- Diameter
- 50mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 41
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 85g/m²
- Pack Count
- 100
- Particle Retention
- 20um
- Pore Size (µm)
- 20.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.