Quantitative Filter Paper - Grade 41, 90mm, 100/pk - 1441-090
More than a hundred years of manufacturing under strict quality standards stand behind Whatman's reputation as a benchmark reference for laboratories worldwide. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. Ashless grade paper seats cleanly in funnels for gravimetric filtration steps and keeps chemical background low for critical gravimetric methods. When a gravimetric determination depends on the filter itself adding no measurable mass, the ashless grade's controlled ash ceiling keeps that determination valid.
Filter Paper Characteristics
- Nominal thickness between 165 and 220 micrometers
- Compatible with hot filtration in gravimetric workflows
- Fast flow rate accelerates filtration of large sample volumes
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Leaves negligible carbon residue
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A clarified acid digest carries only the dissolved fraction to your instrument across the strong-acid matrices your digestion method runs. Connect with the Tisch Scientific team for current stock and lead time on your laboratory order.
- Diameter
- 90mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 41
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 85g/m²
- Pack Count
- 100
- Particle Retention
- 20um
- Pore Size (µm)
- 20.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.