Quantitative Filter Paper - Grade 41, 110mm, 100/pk - 1441-110
Every product line in the Whatman filtration portfolio passes through identical process controls, with rated performance confirmed lot by lot. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. Ashless cellulose construction keeps chemical background low for critical gravimetric methods while seating cleanly in funnels for gravimetric filtration steps and controls ash content to a strict 0.007 percent maximum after ignition. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Basis weight between 75 and 96 grams per square meter
- Fast flow rate accelerates filtration of large sample volumes
- Leaves negligible carbon residue
- Ignites completely on combustion
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Ash content held to a 0.007 percent maximum
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A clarified acid digest carries only the dissolved fraction to your instrument across the strong-acid matrices your digestion method runs. Request blanket-order pricing for your routine laboratory orders from the Tisch Scientific team.
- Diameter
- 110mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 41
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 85g/m²
- Pack Count
- 100
- Particle Retention
- 20um
- Pore Size (µm)
- 20.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
Related Products