Quantitative Filter Paper - Grade 41, 125mm, 100/pk - 1441-125
Whatman's name appears throughout published laboratory literature, a track record that keeps its products cited in documented analytical methods. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. Ashless grade paper controls ash content to a strict 0.007 percent maximum after ignition and seats cleanly in funnels for gravimetric filtration steps. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Ignites completely on combustion
- Nominal thickness between 165 and 220 micrometers
- Compatible with hot filtration in gravimetric workflows
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Leaves negligible carbon residue
- Basis weight between 75 and 96 grams per square meter
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. Not sure which product fits your order? Request a quote and current stock from the Tisch Scientific team.
- Diameter
- 125mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 41
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 85g/m²
- Pack Count
- 100
- Particle Retention
- 20um
- Pore Size (µm)
- 20.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
Related Products