Quantitative Filter Paper - Grade 41, 25mm, 10000/pk - 1441-6309
Whatman now operates as part of Cytiva's life sciences business, gaining a parent company whose manufacturing discipline extends across the bench, the field, and the production floor. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. The ashless grade retains particulates at a fine, gravimetric-grade cutoff and seats cleanly in funnels for gravimetric filtration steps. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Leaves negligible carbon residue
- Ash content held to a 0.007 percent maximum
- Fast flow rate accelerates filtration of large sample volumes
- Adds no measurable mass to a gravimetric determination
- Nominal thickness between 165 and 220 micrometers
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
A filter that contributes mass of its own puts a blank correction between you and the analyte you set out to weigh. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue as the crucible comes to constant weight. For a fast answer on order status or stock availability, start a live chat with the Tisch Scientific team.
- Diameter
- 25mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 41
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 85g/m²
- Pack Count
- 10000
- Particle Retention
- 20um
- Pore Size (µm)
- 20.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.