Whatman now operates as part of Cytiva's life sciences business, gaining a parent company whose manufacturing discipline extends across the bench, the field, and the production floor. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. Ashless cellulose construction keeps chemical background low for critical gravimetric methods while seating cleanly in funnels for gravimetric filtration steps and retains particulates at a fine, gravimetric-grade cutoff. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Ash content held to a 0.007 percent maximum
- Adds no measurable mass to a gravimetric determination
- Compatible with hot filtration in gravimetric workflows
- Heavier 100 to 140 gram per square meter basis weight
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. Request blanket-order pricing for your routine laboratory orders from the Tisch Scientific team.
- Diameter
- 47mm
- Flow Speed
- Slow
- Folded/ Fluted/ Pleated
- No
- Grade
- 42
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 100g/m²
- Pack Count
- 100
- Particle Retention
- 2.5um
- Pore Size (µm)
- 2.5
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Critical Gravimetric Weighing - Grade 42's finest ashless retention at 2.5 microns supports the most demanding precipitate mass determinations.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.