Quantitative Filter Paper - Grade 42, 240mm, 100/pk - 1442-240
Lot-to-lot consistency and complete documentation trace back to Whatman's long-standing manufacturing platform, meeting what analytical laboratories expect as standard. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. Grade 42 retains particulates at the finest ashless cutoff, 2.5 microns and keeps chemical background low for critical gravimetric methods. For critical gravimetric analysis, Grade 42's 2.5-micron retention holds the finely divided precipitate on the disc, and the mass determination stays accurate.
Filter Paper Characteristics
- Slow flow rate provides finer particle capture
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Ash content held to a 0.007 percent maximum
- Compatible with hot filtration in gravimetric workflows
- Nominal thickness between 165 and 220 micrometers
- A 2.5 micron rating gives Grade 42 the finest ashless retention available
A filter that contributes mass of its own puts a blank correction between you and the analyte you set out to weigh. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue as the crucible comes to constant weight. Request blanket-order pricing for your routine laboratory orders from the Tisch Scientific team.
- Diameter
- 240mm
- Flow Speed
- Slow
- Folded/ Fluted/ Pleated
- No
- Grade
- 42
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 100g/m²
- Pack Count
- 100
- Particle Retention
- 2.5um
- Pore Size (µm)
- 2.5
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Critical Gravimetric Weighing - Grade 42's finest ashless retention at 2.5 microns supports the most demanding precipitate mass determinations.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.