Quantitative Filter Paper - Grade 42, 460mm x 570mm, 100/pk - 1442-917
Lot-to-lot consistency and complete documentation trace back to Whatman's long-standing manufacturing platform, meeting what analytical laboratories expect as standard. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. Ashless grade paper seats cleanly in funnels for gravimetric filtration steps while retaining particulates at a fine, gravimetric-grade cutoff and keeps chemical background low for critical gravimetric methods. For critical gravimetric analysis, Grade 42's 2.5-micron retention holds the finely divided precipitate on the disc, and the mass determination stays accurate.
Filter Paper Characteristics
- Compatible with hot filtration in gravimetric workflows
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Nominal thickness between 165 and 220 micrometers
- Slow flow rate provides finer particle capture
- Heavier 100 to 140 gram per square meter basis weight
- A 2.5 micron rating gives Grade 42 the finest ashless retention available
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A clarified acid digest carries only the dissolved fraction to your instrument across the strong-acid matrices your digestion method runs. Send your order details to the Tisch Scientific team for a quote.
- Dimensions
- 460 x 570mm
- Flow Speed
- Slow
- Folded/ Fluted/ Pleated
- No
- Grade
- 42
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 100g/m²
- Pack Count
- 100
- Particle Retention
- 2.5um
- Pore Size (µm)
- 2.5
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.