Quantitative Filter Paper - Grade 43, 150mm, 100/pk - 1443-150
Whatman now operates as part of Cytiva's life sciences business, gaining a parent company whose manufacturing discipline extends across the bench, the field, and the production floor. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. Ashless grade paper controls ash content to a strict 0.007 percent maximum after ignition and keeps chemical background low for critical gravimetric methods. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Basis weight between 75 and 96 grams per square meter
- Ash content held to a 0.007 percent maximum
- Adds no measurable mass to a gravimetric determination
- Nominal thickness between 165 and 220 micrometers
- Ignites completely on combustion
- Fast flow rate accelerates filtration of large sample volumes
A filter that contributes mass of its own puts a blank correction between you and the analyte you set out to weigh. A clarified acid digest carries only the dissolved fraction to your instrument so your ICP and AAS trace results rest on the analyte alone. Request blanket-order pricing for your routine laboratory orders from the Tisch Scientific team.
- Diameter
- 150mm
- Flow Speed
- Medium Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 43
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 95g/m²
- Pack Count
- 100
- Particle Retention
- 16um
- Pore Size (µm)
- 1.5
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
Related Products