Quantitative Filter Paper - Grade 43, 185mm, 100/pk - 1443-185
Lot-to-lot consistency and complete documentation trace back to Whatman's long-standing manufacturing platform, meeting what analytical laboratories expect as standard. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. Ashless grade paper controls ash content to a strict 0.007 percent maximum after ignition while keeping chemical background low for critical gravimetric methods and seats cleanly in funnels for gravimetric filtration steps. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Nominal thickness between 165 and 220 micrometers
- Ash content held to a 0.007 percent maximum
- Compatible with hot filtration in gravimetric workflows
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Adds no measurable mass to a gravimetric determination
- Leaves negligible carbon residue
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. Call the Tisch Scientific team for volume pricing and documentation to support your own product standardization across methods.
- Diameter
- 185mm
- Flow Speed
- Medium Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 43
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 95g/m²
- Pack Count
- 100
- Particle Retention
- 16um
- Pore Size (µm)
- 1.5
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
Related Products