Quantitative Filter Paper - Grade 44, 70mm, 100/pk - 1444-070
Whatman's name appears throughout published laboratory literature, a track record that keeps its products cited in documented analytical methods. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. Grade 44 speeds through gravimetric filtration faster than Grade 42 and controls ash content to a strict 0.007 percent maximum after ignition. When faster filtration matters without loosening the ash ceiling, Grade 44's thinner furnish keeps the gravimetric method on schedule while ash content stays within specification.
Filter Paper Characteristics
- Compatible with hot filtration in gravimetric workflows
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Nominal thickness between 165 and 220 micrometers
- Adds no measurable mass to a gravimetric determination
- Basis weight between 75 and 96 grams per square meter
- Ash content held to a 0.007 percent maximum
A filter that contributes mass of its own puts a blank correction between you and the analyte you set out to weigh. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue so a small, known paper blank is all you correct for. Call the Tisch Scientific team for volume pricing and documentation to support your own product standardization across methods.
- Diameter
- 70mm
- Flow Speed
- Slow
- Folded/ Fluted/ Pleated
- No
- Grade
- 44
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 80g/m²
- Pack Count
- 100
- Particle Retention
- 3um
- Pore Size (µm)
- 3
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Rapid Ashless Filtration - Grade 44's thinner sheet lowers ash weight per sample and speeds routine gravimetric filtration steps.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
Related Products