Quantitative Filter Paper - Grade 44, 125mm, 100/pk - 1444-125
Every product line in the Whatman filtration portfolio passes through identical process controls, with rated performance confirmed lot by lot. Ashless grade filter paper anchors gravimetric analysis workflows in pharma, biotech, and environmental laboratories. Grade 44 uses a thinner ashless sheet than Grade 42 and retains particulates at a fine, gravimetric-grade cutoff. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Ash content held to a 0.007 percent maximum
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Compatible with hot filtration in gravimetric workflows
- Basis weight between 75 and 96 grams per square meter
- Leaves negligible carbon residue
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A clarified acid digest carries only the dissolved fraction to your instrument so your ICP and AAS trace results rest on the analyte alone. Not sure which product fits your order? Request a quote and current stock from the Tisch Scientific team.
- Diameter
- 125mm
- Flow Speed
- Slow
- Folded/ Fluted/ Pleated
- No
- Grade
- 44
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.007%
- Nominal Basis Weight (g/ m²)
- 80g/m²
- Pack Count
- 100
- Particle Retention
- 3um
- Pore Size (µm)
- 3
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Rapid Ashless Filtration - Grade 44's thinner sheet lowers ash weight per sample and speeds routine gravimetric filtration steps.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
Related Products