Quantitative Filter Paper - Grade 50, 125mm, 100/pk - 1450-125
Every product line in the Whatman filtration portfolio passes through identical process controls, with rated performance confirmed lot by lot. Ashless grade filter paper anchors gravimetric analysis workflows in pharma, biotech, and environmental laboratories. Ashless grade paper seats cleanly in funnels for gravimetric filtration steps and keeps chemical background low for critical gravimetric methods. Where acid and trace-metal resistance both matter, the gravimetric method stays on track through a demanding acid digestion without filter failure or ash-ceiling loss.
Filter Paper Characteristics
- Leaves negligible carbon residue
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Compatible with hot filtration in gravimetric workflows
- Slow flow rate provides finer particle capture
- Surface-hardened sheet resists fiber shedding during wet precipitate recovery and transfer
- Basis weight between 75 and 96 grams per square meter
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue so a small, known paper blank is all you correct for. Contact the Tisch Scientific team any time you need volume pricing, order status, or documentation on a product order.
- Diameter
- 125mm
- Flow Speed
- Slow
- Folded/ Fluted/ Pleated
- No
- Grade
- 50
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.015%
- Nominal Basis Weight (g/ m²)
- 115g/m²
- Pack Count
- 100
- Particle Retention
- 2.7um
- Pore Size (µm)
- 2.7
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Low-Ash Gravimetric Work - Grades rated at 0.015 percent ash or below hold filter bias within routine quantitative tolerances.
- Hardened Ashless Filtration - Acid-treated hardened grade adds high wet strength and chemical resistance for demanding gravimetric method conditions.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.