Quantitative Filter Paper - Grade 50, 460mm x 570mm, 100/pk - 1450-917
Whatman's name appears throughout published laboratory literature, a track record that keeps its products cited in documented analytical methods. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. Ashless cellulose construction keeps chemical background low for critical gravimetric methods and seats cleanly in funnels for gravimetric filtration steps. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Compatible with hot filtration in gravimetric workflows
- Leaves negligible carbon residue
- Ignites completely on combustion
- Sheet thickness in the 115 to 160 micrometer range
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Basis weight between 75 and 96 grams per square meter
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue so a small, known paper blank is all you correct for. Request blanket-order pricing for your routine laboratory orders from the Tisch Scientific team.
- Dimensions
- 460 x 570mm
- Flow Speed
- Slow
- Folded/ Fluted/ Pleated
- No
- Grade
- 50
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.015%
- Nominal Basis Weight (g/ m²)
- 115g/m²
- Pack Count
- 100
- Particle Retention
- 2.7um
- Pore Size (µm)
- 2.7
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Low-Ash Gravimetric Work - Grades rated at 0.015 percent ash or below hold filter bias within routine quantitative tolerances.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.