Quantitative Filter Paper - Grade 54, 55mm, 100/pk - 1454-055
More than a hundred years of manufacturing under strict quality standards stand behind Whatman's reputation as a benchmark reference for laboratories worldwide. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. Ashless grade paper seats cleanly in funnels for gravimetric filtration steps and suits trace-metal determinations with minimal metal carryover. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Nominal thickness between 165 and 220 micrometers
- Surface-hardened sheet resists fiber shedding during wet precipitate recovery and transfer
- Basis weight between 75 and 96 grams per square meter
- Low-ash rating with a 0.015 percent ceiling after ignition
- Ignites completely on combustion
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue so a small, known paper blank is all you correct for. Request a quality certificate or lot documentation on your order from our support team, any time.
- Diameter
- 55mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 54
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.015%
- Nominal Basis Weight (g/ m²)
- 90g/m²
- Pack Count
- 100
- Particle Retention
- 22um
- Pore Size (µm)
- 22
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Hardened Ashless Filtration - Acid-treated hardened grade adds high wet strength and chemical resistance for demanding gravimetric method conditions.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Low-Ash Gravimetric Work - Grades rated at 0.015 percent ash or below hold filter bias within routine quantitative tolerances.