Quantitative Ashless Filter Paper - 1454-240
Gravimetric procedures in regulated laboratories require documented ash content that can be reported alongside analytical results for compliance verification. Cellulose purity and documented ash specifications position ashless paper as the standard medium for ignition-based quantitative determinations. By design, controlled manufacturing delivers the documented retention, flow rate, and physical consistency that analytical and preparative filtration methods require.
Key Filter Paper Characteristics
- Acid-washed cellulose construction produces ash content below 0.01%, meeting the blank value requirements of quantitative gravimetric methods.
- Hardened construction withstands aggressive solvents and concentrated acids that would compromise untreated cellulose papers.
- Controlled fiber density balances rapid filtration with complete precipitate capture for efficient quantitative determinations.
- Smooth surface finish facilitates complete precipitate recovery and clean separation from the paper during transfer operations.
- Pure cellulose fiber matrix combines low inorganic residue with the mechanical integrity needed for careful precipitate transfer.
When your application makes the filter paper part of the measurement, the ash and weight specifications above define its analytical contribution. Ashless purity positions this paper as your standard medium for any method where the filter becomes part of the final measurement. Take control of your sample preparation variables and ensure that your data reflects the true nature of your work, rather than the quality of your consumables.
- Diameter
- 240mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 54
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.015%
- Nominal Basis Weight (g/ m²)
- 90g/m²
- Pack Count
- 100
- Particle Retention
- 22um
- Pore Size (µm)
- 22
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Iron Determination - Collects iron hydroxide precipitate for gravimetric determination in ore assay and environmental analysis.
- Lead Quantification - Captures lead sulfate precipitate for gravimetric determination in environmental and industrial samples.
- Chloride Gravimetry - Retains silver chloride precipitate for mass-based chloride determination in water quality and process control.
- Calcium Oxalate Analysis - Captures calcium precipitate for ignition to calcium oxide, supporting clinical and water hardness testing.
- Nickel Determination - Retains nickel dimethylglyoxime precipitate for ignition-based quantification in alloy and plating bath testing.
- Gravimetric Determination - Collects and ignites precipitates for accurate mass measurement with negligible filter blank contribution.