Quantitative Filter Paper - Grade 54, 240mm, 100/pk - 1454-240
Lot-to-lot consistency and complete documentation trace back to Whatman's long-standing manufacturing platform, meeting what analytical laboratories expect as standard. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. The ashless grade retains particulates at a fine, gravimetric-grade cutoff and suits trace-metal determinations with minimal metal carryover. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Leaves negligible carbon residue
- Fast flow rate accelerates filtration of large sample volumes
- Low-ash rating with a 0.015 percent ceiling after ignition
- Ignites completely on combustion
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue so a small, known paper blank is all you correct for. Contact the Tisch Scientific team any time you need volume pricing, order status, or documentation on a product order.
- Diameter
- 240mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 54
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.015%
- Nominal Basis Weight (g/ m²)
- 90g/m²
- Pack Count
- 100
- Particle Retention
- 22um
- Pore Size (µm)
- 22
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Low-Ash Gravimetric Work - Grades rated at 0.015 percent ash or below hold filter bias within routine quantitative tolerances.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Hardened Ashless Filtration - Acid-treated hardened grade adds high wet strength and chemical resistance for demanding gravimetric method conditions.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.