Quantitative Filter Paper - Grade 540, 42.5mm, 100/pk - 1540-042
Whatman now operates as part of Cytiva's life sciences business, gaining a parent company whose manufacturing discipline extends across the bench, the field, and the production floor. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. The ashless grade retains particulates at a fine, gravimetric-grade cutoff while seating cleanly in funnels for gravimetric filtration steps and suits trace-metal determinations with minimal metal carryover. Where acid and trace-metal resistance both matter, the gravimetric method stays on track through a demanding acid digestion without filter failure or ash-ceiling loss.
Filter Paper Characteristics
- Adds no measurable mass to a gravimetric determination
- Compatible with hot filtration in gravimetric workflows
- Leaves negligible carbon residue
- Basis weight between 75 and 96 grams per square meter
- Seats cleanly in standard Buchner and conical funnels for gravity and vacuum filtration
- Surface-hardened sheet resists fiber shedding during wet precipitate recovery and transfer
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue as the crucible comes to constant weight. Contact the Tisch Scientific team any time you need volume pricing, order status, or documentation on a product order.
- Diameter
- 42.5mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Grade
- 540
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.006%
- Nominal Basis Weight (g/ m²)
- 88g/m²
- Pack Count
- 100
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Hardened Ashless Filtration - Acid-treated hardened grade adds high wet strength and chemical resistance for demanding gravimetric method conditions.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.