Quantitative Filter Paper - Grade 540, 150mm, 100/pk - 1540-150
Every product line in the Whatman filtration portfolio passes through identical process controls, with rated performance confirmed lot by lot. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. The hardened ashless grade suits trace-metal determinations with minimal metal carryover and seats cleanly in funnels for gravimetric filtration steps. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Compatible with hot filtration in gravimetric workflows
- Ignites completely on combustion
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Holds integrity through strong acid and strong alkali filtration steps
- Basis weight between 75 and 96 grams per square meter
- Sheet thickness in the 115 to 160 micrometer range
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A clarified acid digest carries only the dissolved fraction to your instrument so your ICP and AAS trace results rest on the analyte alone. Not sure which product fits your order? Request a quote and current stock from the Tisch Scientific team.
- Diameter
- 150mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Grade
- 540
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.006%
- Nominal Basis Weight (g/ m²)
- 88g/m²
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Hardened Ashless Filtration - Acid-treated hardened grade adds high wet strength and chemical resistance for demanding gravimetric method conditions.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
Related Products