Quantitative Filter Paper - Grade 540, 185mm, 100/pk - 1540-185
Whatman's name appears throughout published laboratory literature, a track record that keeps its products cited in documented analytical methods. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. Ashless cellulose construction keeps chemical background low for critical gravimetric methods and controls ash content to a strict 0.007 percent maximum after ignition. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Ash content held to a 0.007 percent maximum
- Ignites completely on combustion
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Compatible with hot filtration in gravimetric workflows
- Surface-hardened sheet resists fiber shedding during wet precipitate recovery and transfer
- Basis weight between 75 and 96 grams per square meter
A filter that contributes mass of its own puts a blank correction between you and the analyte you set out to weigh. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. Request a quality certificate or lot documentation on your order from our support team, any time.
- Diameter
- 185mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Grade
- 540
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.006%
- Nominal Basis Weight (g/ m²)
- 88g/m²
- Particle Retention
- 8um
- Pore Size (µm)
- 8
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Hardened Ashless Filtration - Acid-treated hardened grade adds high wet strength and chemical resistance for demanding gravimetric method conditions.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.