Quantitative Filter Paper - Grade 541, 42.5mm, 100/pk - 1541-042
Every product line in the Whatman filtration portfolio passes through identical process controls, with rated performance confirmed lot by lot. Hardened ashless filter paper undergoes an acid wash during manufacture that strips trace-metal contaminants before packaging. The hardened ashless grade suits trace-metal determinations with minimal metal carryover and controls ash content to a strict 0.007 percent maximum after ignition. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Fast flow rate accelerates filtration of large sample volumes
- Ignites completely on combustion
- Adds no measurable mass to a gravimetric determination
- Holds integrity through strong acid and strong alkali filtration steps
- Compatible with hot filtration in gravimetric workflows
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
A filter that contributes mass of its own puts a blank correction between you and the analyte you set out to weigh. A clarified acid digest carries only the dissolved fraction to your instrument across the strong-acid matrices your digestion method runs. Not sure which product fits your order? Request a quote and current stock from the Tisch Scientific team.
- Diameter
- 42.5mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 541
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.006%
- Nominal Basis Weight (g/ m²)
- 82g/m²
- Pack Count
- 100
- Particle Retention
- 22um
- Pore Size (µm)
- 20.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Hardened Ashless Filtration - Acid-treated hardened grade adds high wet strength and chemical resistance for demanding gravimetric method conditions.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.