Whatman's name appears throughout published laboratory literature, a track record that keeps its products cited in documented analytical methods. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. The hardened ashless grade suits trace-metal determinations with minimal metal carryover and seats cleanly in funnels for gravimetric filtration steps. When a gravimetric determination depends on the filter itself adding no measurable mass, the ashless grade's controlled ash ceiling keeps that determination valid.
Filter Paper Characteristics
- Ignites completely on combustion
- Compatible with hot filtration in gravimetric workflows
- Holds integrity through strong acid and strong alkali filtration steps
- Ash content held to a 0.007 percent maximum
- Sheet thickness in the 115 to 160 micrometer range
- Leaves negligible carbon residue
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. Send your order details to the Tisch Scientific team for a quote.
- Diameter
- 70mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 541
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.006%
- Nominal Basis Weight (g/ m²)
- 82g/m²
- Pack Count
- 100
- Particle Retention
- 22um
- Pore Size (µm)
- 20.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Hardened Ashless Filtration - Acid-treated hardened grade adds high wet strength and chemical resistance for demanding gravimetric method conditions.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.