Quantitative Filter Paper - Grade 541, 185mm, 100/pk - 1541-185
Whatman now operates as part of Cytiva's life sciences business, gaining a parent company whose manufacturing discipline extends across the bench, the field, and the production floor. Ashless grade filter paper anchors gravimetric analysis workflows in pharma, biotech, and environmental laboratories. Ashless cellulose construction keeps chemical background low for critical gravimetric methods and seats cleanly in funnels for gravimetric filtration steps. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Leaves negligible carbon residue
- Compatible with hot filtration in gravimetric workflows
- Basis weight between 75 and 96 grams per square meter
- Ignites completely on combustion
- Holds integrity through strong acid and strong alkali filtration steps
- Adds no measurable mass to a gravimetric determination
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A clarified acid digest carries only the dissolved fraction to your instrument so your ICP and AAS trace results rest on the analyte alone. Connect with the Tisch Scientific team for current stock and lead time on your laboratory order.
- Diameter
- 185mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 541
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.006%
- Nominal Basis Weight (g/ m²)
- 82g/m²
- Pack Count
- 100
- Particle Retention
- 22um
- Pore Size (µm)
- 20.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Hardened Ashless Filtration - Acid-treated hardened grade adds high wet strength and chemical resistance for demanding gravimetric method conditions.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.