Whatman now operates as part of Cytiva's life sciences business, gaining a parent company whose manufacturing discipline extends across the bench, the field, and the production floor. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. The hardened ashless grade suits trace-metal determinations with minimal metal carryover and retains particulates at a fine, gravimetric-grade cutoff. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Slow flow rate provides finer particle capture
- Leaves negligible carbon residue
- Holds integrity through strong acid and strong alkali filtration steps
- Adds no measurable mass to a gravimetric determination
- Surface-hardened sheet resists fiber shedding during wet precipitate recovery and transfer
- Sheet thickness in the 115 to 160 micrometer range
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A low, controlled ash on ignition leaves your precipitate as the bulk of the weighed residue from the crucible through the final weighing. For a fast answer on order status or stock availability, start a live chat with the Tisch Scientific team.
- Diameter
- 185mm
- Flow Speed
- Slow
- Folded/ Fluted/ Pleated
- No
- Grade
- 542
- Hardened (Yes/ No)
- Yes
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.006%
- Nominal Basis Weight (g/ m²)
- 93g/m²
- Pack Count
- 100
- Particle Retention
- 2.7um
- Pore Size (µm)
- 2.7
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- Yes
- Wettability
- Hydrophilic
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Controlled Ash Determinations - Ashless grades cap ash content at 0.007 percent maximum across ignition-based quantitative methods.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.