Quantitative Filter Paper - Grade 589/1, 90mm, 100/pk - 10300009
Whatman's name appears throughout published laboratory literature, a track record that keeps its products cited in documented analytical methods. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. Ashless cellulose construction keeps chemical background low for critical gravimetric methods and retains particulates at a fine, gravimetric-grade cutoff. When a gravimetric determination depends on the filter itself adding no measurable mass, the ashless grade's controlled ash ceiling keeps that determination valid.
Filter Paper Characteristics
- Basis weight between 75 and 96 grams per square meter
- Rated ash content of 0.01 percent or below
- Nominal thickness between 165 and 220 micrometers
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Ignites completely on combustion
- Leaves negligible carbon residue
Undissolved solids riding along in an acid digest reach your instrument and skew the trace-metal figures you report. A clarified acid digest carries only the dissolved fraction to your instrument so your ICP and AAS trace results rest on the analyte alone. Call the Tisch Scientific team for volume pricing and documentation to support your own product standardization across methods.
- Diameter
- 90mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 589/1
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.01%
- Nominal Basis Weight (g/ m²)
- 80g/m²
- Pack Count
- 100
- Particle Retention
- 12-25um
- Pore Size (µm)
- 12.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Low-Ash Gravimetric Work - Grades rated at 0.01 percent ash or below hold filter bias within routine quantitative tolerances.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.