Quantitative Filter Paper - Grade 589/1, 150mm, 100/pk - 10300045
More than a hundred years of manufacturing under strict quality standards stand behind Whatman's reputation as a benchmark reference for laboratories worldwide. Ashless grade filter paper holds ash content to a controlled maximum after ignition for gravimetric determinations. The ashless grade retains particulates at a fine, gravimetric-grade cutoff while seating cleanly in funnels for gravimetric filtration steps and keeps chemical background low for critical gravimetric methods. Where residual ash would confound a gravimetric determination of precipitate mass, the ashless grade's ash ceiling keeps the result trustworthy.
Filter Paper Characteristics
- Nominal thickness between 165 and 220 micrometers
- Compatible with hot filtration in gravimetric workflows
- Fast flow rate accelerates filtration of large sample volumes
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Rated ash content of 0.01 percent or below
- Ignites completely on combustion
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A clarified acid digest carries only the dissolved fraction to your instrument so your ICP and AAS trace results rest on the analyte alone. Not sure which product fits your order? Request a quote and current stock from the Tisch Scientific team.
- Diameter
- 150mm
- Flow Speed
- Fast
- Folded/ Fluted/ Pleated
- No
- Grade
- 589/1
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.01%
- Nominal Basis Weight (g/ m²)
- 80g/m²
- Particle Retention
- 12-25um
- Pore Size (µm)
- 12.0-25.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Low-Ash Gravimetric Work - Grades rated at 0.01 percent ash or below hold filter bias within routine quantitative tolerances.