Quantitative Filter Paper - Grade 589/2, 70mm, 100/pk - 10300108
Whatman's name appears throughout published laboratory literature, a track record that keeps its products cited in documented analytical methods. Analytical methods routinely name the ashless grade by number, letting a validated procedure move between laboratories without paper substitution. Ashless cellulose construction keeps chemical background low for critical gravimetric methods while seating cleanly in funnels for gravimetric filtration steps and retains particulates at a fine, gravimetric-grade cutoff. When a gravimetric determination depends on the filter itself adding no measurable mass, the ashless grade's controlled ash ceiling keeps that determination valid.
Filter Paper Characteristics
- Leaves negligible carbon residue
- Rated ash content of 0.01 percent or below
- Ignites completely on combustion
- Standard substrate for classical gravimetric precipitation methods in analytical chemistry
- Nominal thickness between 165 and 220 micrometers
- Adds no measurable mass to a gravimetric determination
Ash left behind by the filter itself inflates the precipitate mass you weigh after ignition. A clarified acid digest carries only the dissolved fraction to your instrument across the strong-acid matrices your digestion method runs. Contact the Tisch Scientific team any time you need volume pricing, order status, or documentation on a product order.
- Diameter
- 70mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Grade
- 589/2
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.01%
- Nominal Basis Weight (g/ m²)
- 85g/m²
- Pack Count
- 100
- Particle Retention
- 4-12um
- Pore Size (µm)
- 4.0-12.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Soil Suction Measurement - Absorbs moisture in proportion to matric suction for calibrated soil-water potential measurement under ASTM D5298.
- Dissolved Solids Measurement - Ashless paper removes suspended matter while its controlled ash ceiling keeps results within specification.
- Low-Ash Gravimetric Work - Grades rated at 0.01 percent ash or below hold filter bias within routine quantitative tolerances.
- Gravimetric Analysis - Combusts completely during ignition, leaving the retained precipitate isolated from the filter matrix for mass determination.
- Acid Digest Prefiltration - Ashless paper filters mineral acid digests ahead of ICP and AAS analysis, keeping the analytical blank clean.
- Pharmaceutical Analysis Prep - Ashless paper removes suspended particles from drug solutions ahead of pharmacopeial dissolution and assay testing.