Quantitative Ashless Filter Paper - 10300109
Quantitative methods where the filter is ashed alongside the sample require documented, ultra-low residue to protect analytical accuracy. Fine fiber matrix delivers the mechanical integrity needed to transfer collected precipitates from funnel to crucible without loss. In turn, consistent physical properties across the full sheet area support uniform filtration results in both gravity and vacuum applications.
Key Filter Paper Characteristics
- Ash content of <0.01% provides the documented blank value specification that quantitative analytical methods require.
- Non-strengthened grades deliver consistent retention at the economical price point that high-volume routine methods demand.
- Manufactured under controlled acid washing conditions, each sheet delivers consistent ash levels across production lots for method reproducibility.
- Smooth surface finish facilitates complete precipitate recovery and clean separation from the paper during transfer operations.
- Acid-washed cellulose construction produces ash content below 0.01%, meeting the blank value requirements of quantitative gravimetric methods.
Maintaining accreditation requires documented traceability at every step, and the grade specifications above support your audit readiness. Premium cellulose purity reduces the blank correction calculations your gravimetric procedures would otherwise require. Secure your research outcomes by partnering with a filtration solution that understands your need for speed, accuracy, and reproducibility.
- Diameter
- 90mm
- Flow Speed
- Medium
- Folded/ Fluted/ Pleated
- No
- Grade
- 589/2
- Hardened (Yes/ No)
- No
- Material
- Cellulose Fiber
- Nominal Ash Content (%)
- <0.01%
- Nominal Basis Weight (g/ m²)
- 85g/m²
- Pack Count
- 100
- Particle Retention
- 4-12um
- Pore Size (µm)
- 4.0-12.0
- Qualitative/ Quantitative
- Quantitative
- Sterility
- Nonsterile
- Wet Strengthened (Yes/ No)
- No
- Wettability
- Hydrophilic
- Chloride Gravimetry - Retains silver chloride precipitate for mass-based chloride determination in water quality and process control.
- Total Ash Testing - Provides the ultra-low blank needed for accurate ash determination in food, pharmaceutical, and material samples.
- Gravimetric Determination - Collects and ignites precipitates for accurate mass measurement with negligible filter blank contribution.
- Iron Determination - Collects iron hydroxide precipitate for gravimetric determination in ore assay and environmental analysis.
- Lead Quantification - Captures lead sulfate precipitate for gravimetric determination in environmental and industrial samples.
- Aluminum Analysis - Collects aluminum hydroxide precipitate for ignition and weighing in metallurgical and environmental methods.